Your home has a variety of systems you rely on every day. If your electrical, HVAC, or plumbing systems are in trouble, you’ll know it quickly. Look to experts when you need repairs or replacements.
Action Plumbing, Heating, A/C & Electric is your go-to crew for all your home service needs. We know how to resolve any problem with your HVAC, plumbing, or electric systems. We’ll get to the bottom of the problem and provide a lasting solution.
Expert HVAC Services
When the heat and cool hit hard, you need reliable HVAC units to keep your home comfortable. Make sure to count on Action when you need HVAC services in Fitchburg. We offer a wide variety of HVAC services, including:
- 24/7 AC repairs
- AC installations
- AC maintenance
- Furnace services
- Heat pump services
- Boiler services
- Ductless HVAC services
Take good care of your heating and cooling system with professional services from Action. Contact us online or call (608) 291-9165 to get started.
Need help?
608-291-9165Reliable Plumbing
Plumbing issues can crop up at a moment’s notice and you need expert plumbers to provide the help you need. Our team offers plumbing repair, plumbing replacement, and water heater services in Fitchburg, WI.
If your water heater is leaking, it’s vital to have an expert provide repairs. If needed, you may need the whole system replaced. Action can handle the repair or replacement of any brand of water heater.
Plumbing problems could pose a danger in various situations. You may need emergency plumbing services if:
- Your water heater emits a burning smell
- Your pipes have burst and won’t stop flowing
- You have water filling your basement
Trust your plumbing to the pros at Action. Contact us online or call (608) 291-9165 to schedule plumbing services now.
Top-Rated Electric Services
You rely on your electrical services for every type of device and appliance. Trust Action when you need electrical services in Fitchburg. We can repair or install lighting, ceiling fans, electrical panels, and more. If you notice flickering lights, burning smells, or sparks, you need help from expert electricians.
Schedule the electrical services you need most by contacting Action online. Call our office at (608) 291-9165 to learn how we can help.
Why Choose Action?
Since 1989, Action has been resolving problems with plumbing, electric, and HVAC systems. Our team provides same-day service, exceptional customer care, and a dedication to doing the job right. You can trust us when you need repairs, replacements, maintenance, etc.
Trust a local company with decades of experience to handle your essential home system repairs. Contact Action online or call us at (608) 291-9165 to schedule the services you need.
FAQs
What are the signs of a failing water heater?
Water heaters may show various signs that it’s time for repair or replacement. Leaking water, odd noises, and lack of hot water at your faucets are all signs that it’s time to call a plumber.
Can I install my own air conditioner?
While it’s possible to install an AC unit on your own, it’s not a good idea. Only a professional HVAC technician can remove an old unit and install a new one safely and correctly.
When should a breaker be replaced?
Electrical breakers may need replacing if your home’s devices don’t have enough power to operate. You may also need a new breaker if the circuits trip often or the breaker is over 20 years old.
Recent Jobs and Reviews in Fitchburg, WI
Fitchburg, WI at a glance
Action Plumbing, Heating, AC & Electric has completed 20 jobs in Fitchburg, WI between June 2026 and October 2026.
The most recent job was on October 23, 2026.
Action Plumbing, Heating, AC & Electric has completed 51 jobs in Fitchburg, WI in the last 12 months.
Job Locations and Reviews
Performed a full tune-up on the Lennox gas furnace, including cleaning the unit and inspecting and testing its components and operation to confirm proper function. Replaced the air filter as requested. The system was left clean and operating normally.
Performed seasonal maintenance on an 11-year-old Heil gas-fired condensing furnace, including removal of the access panel, cleaning of the blower assembly and internal components, and inspection of wiring, the control board, and the PVC vent and condensate drain line. Verified operation with a digital test instrument and confirmed no visible rust, frost, or damage on the furnace, ductwork plenum, or the attached Aprilaire humidifier; unit was reassembled and left operating normally.
Performed a routine cleaning and safety inspection on a 2015 Lennox gas furnace, including verification of the venting and combustion air PVC piping, ductwork connections, control wiring, and the attached Trion Air Bear air cleaner. Also inspected the gas fireplace insert, finding the glass, ceramic logs, and surround in good condition with no soot, cracks, rust, or visible damage. Both units were left in satisfactory operating condition.
Performed a seasonal tune-up on the 2024 Lennox furnace and the 2003 air conditioning system, including cleaning and inspecting all major components. Verified furnace operation with a combustion analyzer and recorded readings of 7.4% O2, 46 ppm CO, and 7.7% CO2. Inspected the outdoor condenser unit and found it clean and free of visible damage, rust, or ice, with no issues identified during the service.
Completed seasonal heating maintenance and tune-up on 2-year-old Lennox system. Performed comprehensive inspection of furnace components, verified proper combustion efficiency using flue gas analyzer showing oxygen levels at 12.2% and carbon dioxide readings, and inspected ductwork system for proper operation. All system components found operating within normal parameters.
Completed comprehensive furnace cleaning and inspection as part of prepaid maintenance visit. Cleaned flame sensor and condensate trap, verified thermostat wiring connections were secure, installed fresh air filter, and confirmed all components operating within factory specifications. Combustion analysis measured CO at 12 ppm and temperature rise at 48°, both within acceptable parameters for safe and efficient operation.
Responded to no cooling complaint on 2022 Lennox EL15XP1-018-230A01 system blowing warm air. Performed diagnostic inspection including verification of refrigerant charge levels, air filter condition, condensate drain line functionality, and outdoor condenser unit operation. Investigated potential thermostat compatibility issues following recent thermostat replacement to determine if improper wiring or configuration was contributing to system malfunction.
Responded to service call for non-operational furnace on 1.5-year-old unit. Upon inspection, discovered electrical disconnect switch on side of furnace had improper wiring with rubber debris inside connector and inadequate wire connections that were not making proper contact or secured correctly. Removed faulty wiring, cut and installed new wire to top terminal of disconnect switch, and properly secured all connections. Cycled unit through heating and cooling modes to verify proper operation and confirmed furnace now powers on and off correctly.
Completed comprehensive furnace and air conditioning clean and check service. Performed thorough inspection of both heating and cooling systems, measuring supply and return air temperatures to verify proper operation. All equipment found to be functioning within normal operating parameters at time of service.
Completed comprehensive heating maintenance on Lennox furnace system. Performed thorough cleaning of furnace components, conducted operational safety inspection, and verified combustion efficiency using Testo 310 combustion analyzer, which measured carbon monoxide levels at 10 ppm. All system parameters found within normal operating specifications, and unit returned to full operational status.
Responded to furnace not heating correctly with ventilation concerns in upstairs bedroom. Upon arrival, identified multiple supply vents and returns obstructed by curtains, furniture, and beds throughout home. Instructed occupants to remove all obstructions from vents to restore proper airflow. Conducted combustion analysis and discovered elevated carbon monoxide levels at 400 ppm. Adjusted gas pressure from 4 inches to 3.25 inches water column, which reduced CO output to 160 ppm but remained above acceptable levels. Consulted with Bryant technical support, who recommended cleaning gas orifices and manifold. Disassembled burner assembly, removed and cleaned all gas orifices and manifold, then reinstalled components. Post-cleaning combustion analysis showed CO levels reduced to acceptable 49 ppm. Performed comprehensive system inspection and maintenance. Cleaned flame sensor to ensure proper ignition sensing. Tested hot surface igniter, measuring 50 ohms resistance within acceptable r
Completed comprehensive furnace maintenance and safety inspection on Goodman heating unit. Verified igniter resistance at 49.9 ohms within specification, confirmed blower motor operation with free rotation, and measured combustion efficiency at 8 ppm CO with temperature rise of 48°. Performed cleaning of flame sensor, removed and flushed drain trap, inspected and tightened all electrical connections, and blew out pressure switch and ports which were found in clean condition from previous winter replacement. Confirmed thermostat communication and verified system heating operation upon completion.
Responded to no cooling complaint on one-year-old air conditioning system. Upon inspection, found low refrigerant charge and heavily contaminated condenser coil with significant dust and debris accumulation restricting airflow. Thoroughly cleaned condenser coil to restore proper heat exchange efficiency and recharged system with refrigerant to manufacturer specifications. System tested and confirmed operational with proper cooling restored.
Responded to service call for air conditioning system not operating at vacant property. Upon arrival, accessed unit using provided lockbox code and performed diagnostic assessment of outdoor condenser unit and indoor thermostat controls. Inspected outdoor condensing unit positioned against exterior wall, verified electrical connections at disconnect box, and examined conduit routing from unit to wall-mounted disconnect. Checked indoor Honeywell digital thermostat for proper settings and functionality. System evaluated and photographed for documentation purposes.
Performed comprehensive AC clean and check on 24-year-old system utilizing R-22 refrigerant. Inspected electrical components including capacitor and contactor, verified proper operation of all circuits. Assessed refrigerant levels and found unit moderately low on charge, resulting in diminished cooling capacity. Cleaned evaporator coil and drain line to ensure proper condensate removal. Advised customer that unit is operating at minimal efficiency and risks icing up if additional refrigerant loss occurs, strongly recommending system replacement due to age and R-22 phase-out.
Performed complete clean and check maintenance on 2018 Lennox furnace system that had not received service in its 7-year lifespan. Conducted thorough inspection of all furnace components, performed basic cleaning procedures, and verified proper operation of heating system. Additionally addressed air conditioning unit experiencing no cooling condition with lack of cold air output. Deployed manifold gauge set and refrigerant testing equipment at outdoor condensing unit to diagnose cooling system issue and restore proper AC operation.
Performed membership cooling maintenance visit on R-22 system. Completed standard cleaning and operational check of outdoor condenser unit. Identified low refrigerant charge during system evaluation; customer notified of R-22 refrigerant deficiency requiring future attention.
Performed annual clean and check service on older residential air conditioning system. Completed visual inspection of outdoor condenser unit, verified proper fan operation, and performed basic cleaning of exterior components. Unit remains operational and in acceptable working condition for its age.
Completed seasonal air conditioning tune-up on Lennox outdoor condensing unit. Performed thorough cleaning of condenser coil, verified condensate drain line was clear and flowing properly, and conducted standard system diagnostics including refrigerant pressures and electrical measurements. Unit operating within normal parameters upon completion.
Completed comprehensive air conditioning tune-up on Lennox condenser unit, including full system inspection, cleaning of outdoor coil and cabinet, refrigerant pressure verification, and electrical component testing. Unit operating within manufacturer specifications with all safety controls functioning properly. Customer advised system is in good working condition for the cooling season.